Railway Cables | ||||||||||||
Pigtail Rail Connection Cables to SE260L
Application
These connection cables are designed for use in signalling equipment rooms.
Standards
● SE260
● UNE 21123
Construction
Conductors
Stranded plain copper conductors to IEC 60228 class 2 or 5.
Insulation
FRPVC.
Outer sheath
FRPVC.
Optional
Limited fi re hazard pigtail rail connection cables: Stranded tinned copper conductors, LSZH composite insulation.
Electrical Characteristics at 20℃
Nominal Conductor Cross Section | mm² | 0.6 |
Maximum DC Conductor Resistance | Ω/km | 1.15/1.16* |
Voltage Rating | KV | 0.6/1.0 |
*For LSZH cable
Mechanical and Thermal Properties
Minimum Bending Radius: 7.5×OD
Temperature Range:-25℃ to +85℃ (during operation); -10℃ to +70℃ (during installation)
Dimensions And Weight
Cable Code |
No. of cores& Nominal Conductor Cross Sectional Area No.×mm² |
No. & Nominal Diameter of Strands No/mm |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
RF260-VV-K-0.6/1KV-1G16 | 1×16 |
19/1.04 |
0.7 |
1.4 |
10.3 |
249 |
RF260-RZ1-K-0.6/1KV-1G16 | 1×16 |
19/1.04 |
0.7 |
1.4 |
10.3 |
255 |
K is changed to U if the stranding class is changed from class 5 to class 2